Cutting balloon animal study

WebThe following are two techniques for cutting balloon inflation: (1) nominal pressure with a balloon-to-vessel ratio of 1:1 or (2) high pressure using a cutting balloon downsized by … WebFeb 24, 2024 · Patient has lesion that requires the use of adjunctive primary treatment modalities (i.e. laser, atherectomy, scoring/cutting balloon, other debulking devices, etc.) during the index procedure; History of major amputation in the target limb; Target lesion or vessel has ever been previously treated with stent (e.g. in-stent restenosis) or surgery.

SUMMARY OF SAFETY AND EFFECTIVENESS DATA (SSED)

WebThe most widely used cutting balloon in the United States is the Wolverine (successor to the original Flextome) by Boston Scientific (Marlborough, MA). ... Critical assumptions for this method are that all animals move during the course of the study, all animal tracks of the species of interest are readily recognizable, ... WebThe Cutting Balloon is a unique angioplasty device used in percutaneous coronary interventions. The advantage of the Cutting Balloon is its ability to reduce vessel stretch … harrys app https://katieandaaron.net

Recurrent Stenoses in Arteriovenous Fistula (AVF) for Dialysis …

WebThe most widely used cutting balloon in the United States is the Wolverine (successor to the original Flextome) by Boston Scientific (Marlborough, MA). ... Critical assumptions for … WebIn an acute and chronic animal study we compared endo-pyelotomy via a ureteral cutting balloon incision to balloon rupture (that is 30F) of the normal ureteropelvic junction in … WebDec 1, 1991 · In this study we used 1 of the possible designs (Figure 1). One to 4 cutting edges of 0.1 to 0.4 mm metal blades were mounted on the surface of balloon catheters … charles r drew health center

Cutting Balloon Versus Conventional Balloon Angioplasty …

Category:Cutting Balloon Study - Full Text View - ClinicalTrials.gov

Tags:Cutting balloon animal study

Cutting balloon animal study

Optical coherence tomography-guided drug coated balloon in …

WebAug 24, 2024 · For cutting balloon angioplasty in venous stenosis, the primary patency after 12 months is 55-60% (9,16) and in recurrent stenoses up to 48%(10). ... To learn more about this study, you or your doctor may contact the study research staff using the contacts provided below. For general information, Learn About Clinical Studies. Layout table for ... WebMay 13, 2024 · In this study, we selected a new-generation cutting balloon, WOLVERINE TM (Boston Scientific Corporation), with balloon diameters ranging from 2 to 3 mm (2, 2.25, 2.5, 2.75, and 3 mm) and length of 10 mm. The nominal and rated inflation pressures of the cutting balloons are 6 atm and 12 atm, respectively.

Cutting balloon animal study

Did you know?

WebJun 1, 2008 · The diameters of cutting balloons were 5.0 mm, 6.0 mm, 7.0 mm, and 8.0 mm. With use of a 0.018-inch guide wire, the cutting balloons were advanced through a 7-F sheath and appropriately positioned across the target lesion under fluoroscopic guidance. The use of heparin was allowed, with the decision left to the individual physician.

WebJul 21, 2006 · On July 21, 2006, Boston Scientific initiated a voluntary recall of 45 lots/batches of Cutting Balloon Ultra Monorail Devices due to their determination that the … WebSep 23, 2016 · Cutting Balloons Kenneth Chin The cutting balloon is a device having three or four sharp metal microtome blades (0.25 mm high) mounted longitudinally on the …

WebCutting Balloon. Take an in-depth look at the R&D process. Hear from the engineers who developed WOLVERINE Cutting Balloon. WOLVERINE Cutting Balloon delivers industry-leading performance with: improved … WebThis study aimed to explore the optimal method of dilation of highly calcified lesions using a cutting balloon. Calcification models were developed from patient … Efficacy of the …

WebMar 28, 2024 · Cutting balloon has four blades surrounding the balloon, which can cut the plaque. The use of cutting balloon is hindered by problems with crossability; however, a novel cutting balloon (Wolverine™, Boston Scientific, Natrick, MA, USA) with potentially better crossability was recently developed.

WebJun 1, 2015 · Percutaneous balloon angioplasty has been used to treat hemodialysis access stenosis but is complicated by a high rate of restenosis. Percutaneous cutting balloon (PCB) angioplasty is an alternative approach that has shown to reduce restenosis. OBJECTIVES The aim of the study is to assess the safety and efficacy of PCB … charles r drew middle school lincoln alabamaWebJul 15, 2005 · The CB is available as a small vessel device (Cutting Balloon, 139 cm working length, monorail or over the wire, for use with a 0.014-inch guidewire through a … charles r drew hbcuWebApr 29, 2024 · This study will test if rotational artherectomy with the addition of a cutting balloon - a balloon with microsurgical blades on its outer surface which make longitudinal incisions in the calcified area in order to open resistant clogs - will result in increased blood vessel lumen, more optimal stent expansion and decreased cardiac problems … charles r drew middle school miamiWebAbstract: Conservative therapy is typically recommended for patients with spontaneous coronary artery dissection (SCAD). However, percutaneous coronary intervention (PCI) may have to be pursued in cases of ongoing ischemia or hemodynamic instability. There is early and increasing interest in using cutting balloon (CB) angioplasty to fenestrate the false … charles r drew k-8 center miamiWebCutting Balloon as compared to standard balloons.8 ANGIOSCULPT The AngioSculpt Scoring Balloon Catheter (AngioScore, Inc., Fremont, CA) was first developed in ... prospective randomized controlled study comparing the 1-year results of vascular surgery and percutaneous transluminal angioplasty (PTA). Eur J Vasc Surg. 1991;5:517-522. harry sargeantWebDec 10, 2024 · The cutting balloon (CB) 1 is a special balloon catheter with three or four atherotomes (microsurgical blades) bonded longitudinally to its surface, suitable for … harrys appliance alsip ilWeb1 Wu et al, Comparison of Cutting Balloon versus High-Pressure Balloon Angioplasty for Resistant Venous Stenoses of Native Hemodialysis Fistulas, JVIR, 2008, 19: 877-883 2 Aftab et al, Randomized Clinical Trial of … harry sargeant iii